Keyword Reference Guide
MN1270 02.2002 69
DRIVEENABLE = 1
TORQUE = 10
LOOP : PRINT VEL : ENDL
Repeating the torque test should now give the correct polarity.
Note: Changing ENCODERMODE can affect position related keywords
Restrictions:
Must be set after the
CONFIG keyword has been assigned, and again after DEFAULT or LOOPTIME has
been used.
See Also:
ENCODER
ENCODERZACTIVELEVEL/ENL
Purpose:
Specify the active level of the encoder z pulse.
Controllers Supported:
NextMove PCI NextMove PC NextMove BX MintDrive ServoNode 51
Format:
ENCODERZACTIVELEVEL = <expression>
v = ENCODERZACTIVELEVEL
Dot Parameters:
None.
Attributes:
Controller Read Write Command Multi-
Axis
Scaled Default Range
NextMove
1
0 x 1
Description:
The keyword
ENCODERZACTIVELEVEL configures the active state of the encoders Z pulse. Valid
options are:
0 – Encoder Z pulse is considered active when it is low.
1 – Encoder Z pulse is considered active when it is high.
This encoder Z active level is global to all encoders and is not channel specific.
Example:
ENCODERZACTIVELEVEL = 1
Sets the active level of the all encoder Z pulses to be 1.
See Also:
HOME
ENCODERZLATCH/ENZ
Purpose:
To get and reset the state of an axis Encoder Z Latch.
Controllers Supported:
NextMove PCI NextMove PC NextMove BX MintDrive ServoNode 51